Why LWD?

  • 100% original parts
  • Authorized Distributor
  • Close co-operation with the manufacturers
  • Established since 1988
  • Fair prices
  • More than 20,000 products
  • Reliable
  • Wholesale quantities
Attachments:
Download this file (Lawson_BS88_Fuseholders.pdf)Lawson_BS88_Fuseholders.pdf[Lawson Fuse Holders Catalogue]993 kB

 

BOLTIN 660/690V a.c. Fuse-Holders for Fuse-Links to BS88: Part 2 & IEC 60269-2 TYPE LBI

The BOLTIN fuse-holders are available in three versions, front connected, back connected, and front/back connected, in ratings of 20, 32, 63, 100, and 200 Amps. The range fully complies with BS88: Part 2 and is ASTA Certified to a test duty of 80kA at 660V and complies with the current edition of the IEE Wiring Regulations.

 

CLIPFIT 240/415V a.c. Fuse-Holders for Fuse-Links to BS88: Part 6 & IEC 60269-2 TYPE LCF

CLIPFIT fuse-holders provide a simple safe range designed to accommodate the compact dimension fuse-links to BS88: Part 6 and are ASTA ce rtified to the required test duty. Breaking capacities are 50kA at 240V a.c. and 80kA at 415V a.c. CLIPFIT is available in 20, 32, and 63 Amp ratings, and incorporates an integral DIN rail mounting facility as well as single screw fixing. Front connected, back connected, front/busbar connected and front/back connected
configurations are available in black or white as standard colours.

 

FUSE- BANKS TYPE FB/FZ

Both the BOLTIN and CLIPFIT fuse-holders can be supplied as pre-assembled fuse-banks. The fuse-banks consist of single phase assemblies of shrouded busbar connected fuse-holders mounted on a back rail for incorporation into standard and heavy duty distribution fuseboards to facilitate compliance with BS 5486: Part 1, EN60439 - 1 and BS 5486: Part 11. The fuse-banks may be mounted either horizontally or vertically. A fully insulated incoming terminal shroud can be positioned to accept cable entry from varying directions.

 

PULLCAP MODULAR FUSE-HOLDERS TYPE LPC

The PULLCAP 240/415 V a.c. modular fuse-holders incorporate fuse-links to BS88: Part 1 and BS1361. Note: Individual components are available as fully assembled LPCU units rated at 5, 20, 32 & 63 Amps.

 

SLYDLOK FUSE-HOLDERS TYPE SLY

 

MODULAR FUSE-HOLDERS FOR FUSE-LINKS IN ACCORDANCE WITH IEC 60269 -2 TYPE MS

The MS range of modular fuse-holders offer fuse protection in four popular frame sizes in voltage ratings up to 660 Va.c. Modular fuse-holders accept cylindrical fuse-links up to a maximum rating of 125 Amps, with principle dimensions of 8.5 x 31.5, 10.3 x 38, 14 x 51 and 22 x 58mm. Conversion kits are available to assemble 2,3 or 4-pole units.

 

DOUBLE POLE CUT-OUT TYPE SLFK

This compact Cut-Out has been designed to comply with the latest requirements of the Wiring Regulations and the Electricity at Work Act. It has been rated at 32A, 415Va. c., incorporates fully shrouded top terminals and utilises fuse-links reference F1 to BS88:Part 6.